The table below lists the maximum length for both 1/2″ and 3/4″ gas lines when paired with Rinnai tankless water heater models.
Rinnai Tankless Water Heater Models |
Name Plate Ratings (BTU/H) |
SCH 40 Metallic Pipe Size (Maximum Equivalent Length) |
|
|---|---|---|---|
1/2 Inch |
3/4 Inch |
||
| V53e | 120,000 | 100′ | 450′ |
| V65e, V65i | 150,000 | 70′ | 300′ |
| RUC80i, RU80i | 152,000 | 70′ | 166′ |
| RL75i, RL75e | 180,000 | 50′ | 200′ |
| V75i, V75e | 180,000 | 50′ | 200′ |
| RLX94i | 192,000 | 40′ | 175′ |
| RUC98i, RU98e | 199,000 | 40′ | 175′ |
| RL94i, RL94e | 199,000 | 40′ | 175′ |
| INTENDED USE: Initial Supply Pressure: 8.0″ w.c. or greater; Inlet Pressure: <2 psi; Pressure Drop: 3.0″ w.c.; Specific Gravity: 0.60 | |||
| Source: NFPA 54/ ANSI X223.1 National Fuel Gas Code | |||
Here are the steps needed to properly size your gas line:
- Determine what type of gas is being used
- Determine inlet pressure
- Determine the allowed pressure drop
- Determine what other types of gas appliances are sharing the gas line
- Determine the maximum loads expected on the whole system as stated in the National Fuel Gas Code