TANKLESS WATER HEATER
INSTALLATION
Installation: Key points.
• Rinnai HE+ series and SE+ series water heaters can be used in both residential and commercial
applications.
➢ The HE series and SE series models are for residential applications only.
➢ The C199 models are for commercial applications only.
• Rinnai tankless water heaters are manufactured in natural gas or propane versions.
• Indoor models must be installed within the confines of a structure and vented to the outside.
• Outdoor models must be installed outside where the exhaust can be vented directly from the
front of the water heater.
• Residential installations are potable water applications in single family dwellings with a
maximum water temperature setting of 140⁰F.
• Commercial installations are potable water applications for restaurants, schools, hotels, car
washes, coin laundries, assisted living facilities, etc.
• For commercial applications requiring water temperatures over 140⁰F, an optional MCC-91
temperature controller allows a maximum water temperature setting up to 160⁰F or 185⁰F
(depending on the model).
• The Commercial specific C199 models do not need the MCC-91-2 controller to achieve 185⁰F.
• The maximum operating temperature for the RUR models is 140⁰F.
PLEASE NOTE ANY GAS APPLIANCE MAY ONLY BE INSTALLED BY A REGISTERED GAS INSTALLER.
• If the water heater is installed in an area where water leakage from the unit or the plumbing
connections could result in water damage to the area surrounding the appliance or to floors or
lower levels of the structure, it is recommended that a suitable drain pan be installed under
the appliance. The drain pan must not restrict air flow.
• If the water heater is installed in a closed water supply system, such as one having a backflow
preventer in the cold water supply line, means shall be provided to control thermal expansion.
➢ Water heaters utilizing a circulation system will require the installation of an expansion
tank.
• DO NOT use Rinnai water heaters in applications such as a pool or spa heater that uses
chemically treated water.
➢ The water heater is suitable for filling large tubs or whirlpool spa tubs with potable
water.
• If the water heater is installed in a area that is known to have hard water or water that causes
scale build-up, the water must be treated and may require more frequent service (flushing of
the heat exchanger).
It is important to ensure the following incoming sources fall within specifications:
• Electricity –
➢ A properly polarized and grounded 120 VAC, 60 Hz power supply is required (the
temperature controller operates on 12 VDC. This voltage is supplied by the water heater main circuit
board).
• Water –
➢ Pipe sizing and incoming water pressure must meet each model’s requirements as stated
in the installation manual and, water quality must meet the EPA’s National Secondary
Drinking Standards.
• Gas –
➢ Adequate gas pressure and volume (gas line sizing) must be verified for proper operation.
• Venting (air) –
➢ Only the vent components that are certified and listed with the water heater can be used.
The venting must be installed per specifications and proper clearances must be
maintained.
❖ All national, state, and local codes must be followed.
Installation: Isolation valve kit.
• Rinnai recommends the use
of an isolation valve kit when
connecting the water lines to
the water heater.
• This kit includes hot and cold
water shut-off valves, hot and
cold water drain valves, and an
ANSI approved pressure relief
valve.
• This kit meets all individual
states’ lead-free standards.
• Use of the kit allows flushing
of the heat exchanger as well
as aids in servicing and
troubleshooting.
VENTING
REQUIREMENTS
• Follow proper vent installation guidelines.
• Do not mix venting components between non-condensing
and condensing models or between different
manufacturers as dangerous conditions could occur!
! WARNING
Improper installation of vent system components, or
failure to follow installation instructions, could result
in property damage or serious injury or death!
Rinnai tankless water heaters are direct vent
appliances and therefore are certified and listed with
the vent system.
• You must use ONLY the vent components that are
certified and listed with the water heater.
Tested, Certified and Listed vent materials for the HE
and HE+ indoor models.
Manufacturer Product
Rinnai / Ubbink Rolux Vent System (available from Rinnai)
Heat-Fab Saf-T Vent SC system
Metal-Fab Corr/Guard Vent/Air Intake System
• The water heater models listed above utilize a
concentric vent system which allows for zero clearance
to combustible materials.
➢ Approved venting can be connected directly to the water
heater.
➢ The vent connection also incorporates a condensate
collector.
The maximum vent length for Non-condensing
models is 41 equivalent feet.
When calculating the equivalent vent length, each
90⁰ elbow is equal to 6 feet and each 45⁰ is
equal to 3 feet.

• If the vent length equivalency is greater than 21
feet, move DIP switch #1 on the PCB (in the upper
group of switches) to the OFF position.
(this switch is shipped in the ON position)
• Comply with all vent guidelines – refer to vent manufacturer installation instructions.
• The water heater’s maximum water flow capacity will be reduced slightly when DIP switch no.
1 is OFF.
Temperature Controllers