Gas Boosted Solar Hot Water with Rinnai Water Heaters

Conventional solar systems work by transferring the suns rays to heat water, which is then stored inside solar storage tanks.  Once this finite amount of solar heated water expires, the electrical backup will sense the drop in water temperature stored and activate the electrical element to start heating water, which can take up to 3 hours.

Rinnai Water Heaters gas can be easily utilised as in-series gas hot water boosters for Solar Systems, or as pre-heaters for hot water systems.  It can simply be retrofitted to the hot water outlet of a solar storage tank.

The gas booster sits idle as solar heated water passes it through as long as the water temperature is above 58 degrees.  When the solar heated water temperature passes through the gas water heater below 58 degrees, the gas booster will ignite to boost the supplied water temperature for use.

The gas geyser is used as a gas booster for periods of low solar energy gain – such as cloudy weather, cold days, night time, rainy days and during winter months.  By using a Rinnai gas geyser as a gas booster, you can eliminate the electrical backup and take advantage of instant hot water, only when it is required.

Features:

  • Unlimited Hot Water available
  • Easy Outdoor Installation
  • Easily retro-fitted to existing solar systems
  • Only pay for the water you heat (GWH sits on standby ready to fire up when needed)
  • Make your existing solar even more efficient

As You Can see from the two video’s there is great benifit to Lagging your water pipes.

SANS 10106 and the PIRB certificate of 

02 Apr 2015 9:38 AMAnonymous
By: Martin Coetzee – technical officer at IOPSA 

The Institute of Plumbing South Africa (IOPSA) takes a look at South African National Standards (SANS) 10106 and how it affects solar water heating installations 

Numerous laws, regulations, bylaws, contract and tender specifications, service level agreements, rebate terms of reference etc., require that solar water heating installations must comply with SANS 10106 for the installation, repair and replacement of domestic solar water heating systems. 

It has been seen by some as a market disadvantage to the good plumbers who do correct installations but who then get undermined by the bad plumbers who either don’t know what the SANS standards require, or they are in the business of cutting corners and quoting lower prices by using materials that don’t comply with SANS standards. The enforcement mechanisms in the plumbing industry are the municipal water/sanitation and building inspectors and the Plumbing Industry Registration Board (PIRB) certificates of compliance (COC) with built-in percentage inspection mechanisms. 

Section 9 of SANS 10106: 2014 now makes the issuing of a COC a requirement, the same as an electrician must issue an electrical COC for the electrical installation. This section reads, ‘9.1 – A plumbing COC from the plumbing professional body registered under the relevant national body [the South African Qualifications Authority (SAQA)] shall be issued …where work has been carried out on the hot water reticulation system which includes the installation of a solar system.’ The professional body for plumbing registered with SAQA is the PIRB. 

A solar water heating system is therefore not SANS 10106 compliant if a PIRB certificate has not been issued. It is important for plumbers who are complying with the legal requirements regarding all solar water heating installations, to ensure that their clients and potential clients are aware that they are in fact PIRB registered and do issue PIRB COC in full compliance with SANS 10106, as required. Such COCs will also be required for insurance cover of the installation. This now levels the playing fields so that the minimum level for competing in the market are the requirements of SANS 10106, nothing less. It is therefore in your interest to obtain a copy of SANS 10106: 2014 edition 4 and make yourself familiar with its requirements. 

The practice of doing solar installations without being properly qualified, not using compliant materials and not issuing PIRB COC is now illegal in terms of the National Building Regulations, the Water Services Act, the Occupational Health and Safety Act, the water and sanitation bylaws, and the Consumer Protection Act

 

What is a tempering valve ?

And how is this nessesary when using it conjunction between a Gas Water Heater & a Solar Geyser. 

 

Image result for tempering valve

What is a tempering valve? A tempering valve is a 3-way mixing valve which is temperature actuated and used to temper a heated water supply by mixing the heated water with cold to feed heated water at a reduced temperature to the taps around your home.

Tempering valve is designed to control the flow of the water circulating from a heat pump / solar System.

# High/ low pressure
# Thermostatically controlled mixing valve to prevent scalding from hot water supply.

Factory set and locked to give 55° C outlet.
# Adjustment from 35°C to 60°C
# Inlet hot water supply : 65°C to 99° C
# Extremely high flow rate makes it suitable for low pressure systems
# Check valves Incorporated at both inlet/outlet on HP valves

Forged high quality DZR brass high resistant hot water proof internal components

SANS 10106:2006
Edition 3
13
Annex A
(informative)
Design considerations and positioning of solar collectors
Solar heaters effectively absorb heat from the sun from about 10:00 until about 16:00. Solar
irradiance is at its peak between about 12:00 and 14:00. However, sufficient quantities of hot water
have to be stored for use after 16:00.
A critical factor in the installation of solar heating systems is the position of the collector relative to
the movement of the sun. In the southern hemisphere, collectors should be pointed true north and
tilted at an angle above the horizontal equal to the latitude of the site plus 10°. This angle is chosen
mainly to favour the collection of solar heat during winter1) when the sun is fairly low in the sky, to
obtain year round efficiency. A deviation of up to 45° east or west of north may, however, be
acceptable in many cases.
The design of the absorber unit can vary from a simple flat plate to an evacuated tube reflector type
absorber.
Ideally, the exposed surface of the collector should absorb the maximum amount of incident solar
radiation with a minimum of heat loss.
The transparent cover over the collector prevents ingress of rain, reduces the cooling effect of
outside air movement over the collector and restricts re-radiation losses, the latter probably being
the most important. This means that the incident solar radiation has to be transmitted through the
transparent cover with a minimum loss of heat energy due to absorption.
Thermosiphonic circulation can be created by placing the absorber at the lowest point of the
system. The resulting circulation pressure is fairly small and any obstruction or an accumulation of
air bubbles in the system can impede the natural flow of the water. The absorber and all pipes are
therefore sloped in such a way that air can escape to the tank to be vented off.
While the thermosiphonic system, as shown in figure 2, is the most popular one for domestic
applications, pumped systems permit greater freedom in the placement of the absorber(s), which
can then be situated either above or below the storage tank. A typical pumped system is shown in
figure 3. Pumped systems can be direct (where the potable water itself circulates through the solar
collector) or indirect as shown in figure 4, where the potable water is heated via a heat exchanger.
In an indirect system, additives can be added to the solar panel water (or primary circulating water)
to control corrosion. Figure 5 shows a more complex arrangement in which a solar installation is
used to preheat the feed tester for the main hot water storage tank.
Indirect systems are less efficient than direct systems, owing to losses from the heat exchanger.
Indirect systems do, however, have the following advantages over both thermosiphonic and
pumped direct systems:
a) frost damage can be prevented by the use of a suitable heat transfer fluid, usually water with an
antifreeze additive;
b) damage due to boiling can be prevented if a suitable heat transfer fluid with a high boiling
temperature is selected;
c) corrosion within the primary system can be minimized by the use of a corrosion-inhibited heat
transfer fluid; and
d) scale formation within the primary system can be more effectively controlled.

1) A shallower angle may be chosen in winter rain regions.

 SANS 10106:2006
Edition 3
6
5.3 Solar storage tank
5.3.1 The minimum storage capacity of a container in any solar hot water system shall, unless
otherwise required (see annex B), be as follows:
a) if no supplementary energy source is provided, a storage capacity of 20 % in excess of the daily
hot water demand under winter conditions;
b) if a supplementary energy source is provided,
1) for an integral solar heater system, a storage capacity of at least 100 % of the daily hot water
demand under summer conditions, and
2) for an integral solar heater and supplementary storage container system, a storage capacity of
i) in the case of the solar container, at least 25 % of the daily hot water demand under
summer conditions, and
ii) in the case of the supplementary container, at least 75 % of the daily hot water demand
under summer conditions.
5.3.2 Where heat losses might occur, the storage tanks shall be thermally insulated in an
acceptable manner to prevent heat loss.
5.3.3 When the storage tank (complete with its ancillary components) is installed in a manner and
position where any leakage from the storage tank and its ancillary components can cause any
damage to property, it shall be furnished with a drip tray, and
a) such a drip tray shall be fitted with a discharge pipe connected to the discharge connection of the
drip tray and be led through an external wall in a visible position in order to discharge on the
outside of the building; and
b) the joint between the discharge pipe and discharge connection of the tray (see (a)) shall be made
leaktight.
5.3.4 Where the storage tank is fitted with an overflow valve, the outlet thereof shall be directed to
where it shall not cause damage to the building.
5.4 Safety devices and controls
5.4.1 Control systems components shall comply with the relevant national or international
standards.
5.4.2 Pressure relief and temperature relief valves shall be installed in those parts of the system
which can be isolated and contain a heat source.
5.4.3 The system shall incorporate a means of alerting the user of the malfunctioning of the
system.
5.4.4 Systems that rely on air to facilitate drainage shall be fitted with vacuum breakers that
comply with the requirements of SANS 198.
5.4.5 Where the temperature of the stored water is not set to 60 °C, the system shall be fitted with
a mixing valve. 

 

Scalding

Water above 43°C carries a scalding risk. The hotter the water, the shorter
the contact time required to cause scalding. Building Regulations require
that, for new dwellings or those formed by a material change of use, the
discharge temperature for bath taps should be limited by a thermostatic
mixing valve (TMV) to 48°C (see bath, basin and sink fittings on page
20 and Building Regulations part G on page 50). Kitchen taps can still
supply water at full temperature which may be over 60°C. Older bathroom
installations still result in scalding incidents. Young children and the elderly
are particularly at risk of scalding as they may not react quickly enough to
avoid injury when coming into contact with unexpectedly hot water.

SANS 10106. Description. Does the installaton comply with relevant national legislation. Solar water heater complies to SANS 1307. Hot water to terminal fittings .